Then looking at that photo again you can see i have a 30a 2 pole breaker at the other end for my solar inverter.
Backfeed breaker solar.
The transfer switch or interlocked backfeed breaker acts to prevent the connection of the generator while the main breaker for the panel is closed.
The main purpose of the fuses and breakers are to protect the wiring.
We sometimes see people adding a 60 or 80 a breaker instead.
According to the manual backfeeding is a real grid tie system once the grid is off the backfeeding stops.
In my case i have 1 6kw solar but 9 6kwh golf battery system it will never get fully charged unless i choose so.
Nec705 12 b 2 3 b states that where there are two power sources the grid and the solar inverter the sum of their breakers cannot equal more than 120 of the busbar rating of the breaker box.
The backfeed generator breaker can t be closed while there is main power on the panel and when there is a power failure it can only be closed after the main breaker is open.
The problem is the backfeeding only happens when battery is fully charged.
So you always want to be sure your sizing your wire to handle the output of each circuit in the system.
Circuit requirements are outlined in part ii of this article.
Article 690 requirements apply to solar pv systems.
690 10 e plug in type back fed circuit breakers connected to a stand alone inverter output in either stand alone or utility interactive systems shall be secured in accordance with 408 36 d.
As noted in sec.
From there you d land your inverter s output into a 50a breaker and your done.
Energizing wiring systems far from your setup like this can damage your equipment and the appliances being powered as well as potential for electrocution to technicians repairing power lines.
The sizing of back feed breakers is another point of difficulty.